Disel generator
Aksa APD 825 M

Model : APD 825 M
Product : MITSUBISHI
CONTROL SYSTEM : DSE 7320
Introduction

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.

Сertificate
  TS ISO 8528
  TS ISO 9001-2008
  CE
  SZUTEST
  2000/14/EC
General Characteristics
Model Name APD 825 M
Frequency (Hz) 50
Fuel Type Diesel
Engine Made and Model MITSUBISHI - S6R2-PTAA
Alternator Made and Model Mecc Alte - ECO 40-VL/4 B 
Control Panel Model DSE 7320 
Canopy MS 86
3 Phase, 50 Hz, PF 0.8
VOLTAGESTANDBY RATING (ESP) (ESP)PRIME RATING (PRP) (PRP)
kVAkWkVAkWAmp
400/231 825 660.0 750 600.0 1190.82
STANDBY RATING (ESP) (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.

PRIME RATING (PRP) (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.
Engine Specifications
Engine MITSUBISHI
Engine Model S6R2-PTAA
NO. OF CYLINDERS AND BUILD 6 cylinders - in line
BORE AND STROKEmm 170 X 220
TOTAL DISPLACEMENTL 29.96
Aspiration Turbo Charged and After Cooled
COMPRESSION RATIO 14.0:1
RATED SPEED (RPM)d/dk 1500
OIL CAPACITYL 94
Standby Power (kW/HP) 730/978 kW
Prime Power (kW/HP) 665/892 kW
Block Heater QTY
  1
Block Heater Power (Watt)
  3000
Fuel Type
  Diesel
Injection Type and System
  Direct
Type of Fuel Pump
  Mitsubishi PS6 (In-Line)
Governor System
  Electronic
Operating Voltage (Vdc)
  24 Vdc
Battery and Capacity (Qty/Ah)
  2x143
Charge Alternator (A)
  30
Cooling Method
  Water Cooled
Cooling Fan Air Flow (m3/min)
  726
Coolant Capacity (engine only / with radiator) (lt)
  14.5/132
Air Filter
  Dry Type
Fuel Cons. Prime With %100 Load (lt/hr)
  156.7
Fuel Cons. Prime With %75 Load (lt/hr)
  119.2
Fuel Cons. Prime With %50 Load (lt/hr)
  81.5
Alternator Specifications
Manufacturer Mecc Alte
Alternator Made and Model ECO 40-VL/4 B
Frequency (Hz)Hz 50
Power (kVA)kVA 750
DESIGN   4 Pole,  Brushless
VOLTAGEV 400
Phase 3
A.V.R. DER1
Voltage Regulation(+/-) 0.5
Insulation System H
Protection IP23
Rated Power Factor 0.8
COOLING AIR (m³/min)m3 54
Size and Weight
Open TypeDRY WEIGHT (kg.)
(kg.)
LENGHT
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
6360 4100 1800 2180 1300
CANOPYDRY WEIGHT (kg.)
(kg.)
LENGHT
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
MS 86
7680 5410 1860 2650 1150
Standart Specifications

Heavy duty, water cooled diesel engine 
Radiator with mechanical fan 
Protective grille for fan and rotating parts 
Electric starter and charge alternator 
Starting battery (with lead acid) including rack and cables 
Engine jacket water heater 
Steel base frame and anti-vibration isolators 
Fuel tank under the base frame 
Flexible fuel connection hoses 
Single bearing, class H alternator 
Industrial exhaust silencer and steel bellows supplied separately 
Static battery charger 
Manual for application and installation 
Generators Sets’ voltage and frequency regulation comply with ISO 8528-5 
Generators Sets’ can take 100% load at one step according to NFPA110

Optional Equpiments

ENGINE
• Remote Radiator Cooling
• Fuel-Water Seperator Filter
• Oil heater
ALTERNATOR
• Anti-Condensation Heater
• Main line circuit breaker
CONTROL SYSTEM
• Automatic synchronising and power control system ( multi gen-set Parallel )
• Paralel system with mains.
• Transition synchronization with mains
• Remote relay output
• Alarm output relays
• Remote communication with modem
• Earth fault, single set
• Charge Ammeter
TRANSFER SWITCH
• Three or four pole contactor
• Three or four pole motor operated circuit breaker
OTHER ACCESSORIES
• Main Fuel Tank
• Automatic or manual fuel filling system
• Manual oil drain pump
• Low and high fuel level alarm
• Residential silencer
• Enclosure: weater protective or sound attenuated
• Duct adapter ( on radiator)
• Inlet and outlet motorised louvers
• Inlet and outlet acoustic baffles
• Tool kit for maintenance
• 1500/3000 hours maintenance kit
• Supplied with oil and coolant - 30 °C

Download
Get FREE expert advice in 15 minutes
Special offers