Disel generator
Aksa AMT 33

Model : AMT 33
Product : MITSUBISHI
CONTROL SYSTEM : DSE 6020
Introduction

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.

Сertificate
  TS ISO 8528
  CE
  SZUTEST
  2000/14/EC
General Characteristics
Model Name AMT 33
Frequency (Hz) 50
Fuel Type Diesel
Engine Made and Model MITSUBISHI - S4S
Alternator Made and Model Stamford - PI144G 
Control Panel Model DSE 6020 
Canopy AK 20
3 Phase, 50 Hz, PF 0.8
VOLTAGESTANDBY RATING (ESP) (ESP)PRIME RATING (PRP) (PRP)
kVAkWkVAkWAmp
400/231 33 26.4 30 24.0 47.63
STANDBY RATING (ESP) (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528. Overload is not allowed.

PRIME RATING (PRP) (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation,in accordance with ISO 3046.
Engine Specifications
Engine MITSUBISHI
Engine Model S4S
NO. OF CYLINDERS AND BUILD 4 cylinders - in line
BORE AND STROKEmm 94 X 120
TOTAL DISPLACEMENTL 3.331
Aspiration Naturally Aspirated
COMPRESSION RATIO 22.0:1
RATED SPEED (RPM)d/dk 1500
OIL CAPACITYL 10
Standby Power (kW/HP) 31,6/42,35 kW
Prime Power (kW/HP) 28,7/38,47 kW
Block Heater QTY
  1
Block Heater Power (Watt)
  500
Fuel Type
  Diesel
Injection Type and System
  Indirect
Type of Fuel Pump
  Bosh In-Line
Governor System
  Mechanic
Operating Voltage (Vdc)
  12 Vdc
Battery and Capacity (Qty/Ah)
  1x55
Charge Alternator (A)
  50
Cooling Method
  Water Cooled
Coolant Capacity (engine only / with radiator) (lt)
  5.5/20.7
Air Filter
  Dry Type
Alternator Specifications
Manufacturer Stamford
Alternator Made and Model PI144G
Frequency (Hz)Hz 50
Power (kVA)kVA 30
DESIGN   Brushless
VOLTAGEV 400
Phase 3
A.V.R. AS480
Voltage Regulation(+/-) 1
Insulation System H
Rated Power Factor 0.8
COOLING AIR (m³/min)m3 6
Size and Weight
Open TypeDRY WEIGHT (kg.)
(kg.)
LENGHT
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
630 1490 900 1110 70
CANOPYDRY WEIGHT (kg.)
(kg.)
LENGHT
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
AK 20
850 2096 960 1500 70
Standart Specifications

Water cooled, Diesel engine 
Radiator with mechanical fan 
Protective grille for rotating and hot parts 
Electric starter and charge alternator 
Starting battery (with lead acid) including rack and cables 
Engine coolant heater 
Base frame design incorporates an integral fuel tank and anti-vibration isolators 
Flexible fuel connection hoses 
Single bearing, class H alternator 
Industrial exhaust silencer and steel bellows supplied separately(for open sets) 
Static battery charger 
Manual for application and installation 
Generators Sets’ voltage and frequency regulation comply with ISO 8528-5 
Generators Sets’ can take 100% load at one step according to NFPA110

Optional Equpiments

ENGINE
• Remote Radiator Cooling
ALTERNATOR
• Main line circuit breaker
CONTROL SYSTEM
• Charge Ammeter
TRANSFER SWITCH
• Three or four pole contactor
• Three or four pole motor operated circuit breaker
OTHER ACCESSORIES
• Main Fuel Tank
• Automatic or manual fuel filling system
• Manual oil drain pump
• Residential silencer
• Enclosure: weater protective or sound attenuated
• Trailer
• Tool kit for maintenance